Tags: LTX Units

LTX Unit Condensate Stabilizer

{0 Comments}

It should be clear from the description of LTX units that the lower pressure separator in an LTX unit is a simple form of cold-feed condensate stabilizer. In the cold, upper portion of the separator some of the intermediate hydrocarbon components condense. In the hot, lower portion some of the lighter components flash. An LTX …

Read More…

LTX Coil Lengths Sizing

{0 Comments}

LTX Coil Lengths Sizing

With the known temperatures on each end of the coil, the heat duty for each coil can be calculated from the heat transfer theory. Since the bath is at a constant temperature, LMTD can be calculated as: The overall film coefficient, U, for the coil can be calculated or read from the charts and tables …

Read More…

LTX Wall Thickness Sizing

{0 Comments}

LTX Wall Thickness Sizing

Before choosing a wall thickness it is necessary to choose a pressure rating for the coil. Typically, the high-pressure coil (L1) is rated for the shut-in pressure of the well, and the low-pressure coil (L2) is rated for the maximum working pressure of the downstream equipment. There are many exceptions to this rule and reasons …

Read More…

LTX Coil Diameter Sizing

{0 Comments}

LTX Coil Diameter Sizing

Erosional flow criteria will almost always govern in choosing the diameter. Sometimes it is necessary to check for pressure drop in the coil. Typically, pressure drop will not be important since the whole purpose of the line heater is to allow a large pressure drop that must be taken. The allowable erosional velocity is given …

Read More…

LTX Coil Temperatures Sizing

{0 Comments}

In order to choose the coil length and diameter, a temperature must first be chosen upstream of the choke; the higher Th the longer the coil L] and the shorter the coil L2. In Heat Transfer Theory we showed that the greater the LMTD between the gas and the bath temperature, the greater the heat …

Read More…

Fire Tube Sizing

{0 Comments}

Fire Tube Sizing

The area of the fire tube is normally calculated based on a heat flux rate of 10,000 Btu/hr-ft2. The fire-tube length can be determined from: where L = fire tube length, ft q = total heat duty, Btu/hr d = fire tube diameter, in. A burner must be chosen from the standard sizes in Table …

Read More…

LTX Units Heat Duty

{0 Comments}

LTX Units Heat Duty

To calculate the heat duty it must be remembered that the pressure drop through the choke is instantaneous. That is, no heat is absorbed or lost, but there is a temperature change. This is an adiabatic expansion of the gas with no change in enthalpy. Flow through the coils is a constant pressure process, except …

Read More…

LTX Units

{0 Comments}

LTX Units

These units are designed to allow hydrates to form and to melt them with the heat of the incoming gas stream before they can plug downstream equipment. In addition, the low-temperature separation that occurs in an LTX unit results in stabilizing the liquids. This results in an increase in liquids recovered and a corresponding decrease …